PART ONE — SUTURES


1. The Four Questions

Every suture choice answers four questions:

  1. Does it need to dissolve? — absorbable vs non-absorbable
  2. How long does the tissue need support? — days, weeks, or forever
  3. Is infection a concern? — monofilament vs braided
  4. What is the tissue? — determines needle type and suture size

Get those four right and the specific brand matters much less than people pretend.


2. Absorbable vs Non-Absorbable

Absorbable sutures lose tensile strength and are then broken down — by hydrolysis (synthetic) or proteolysis (natural). Two separate timelines matter and people conflate them:

  • Tensile strength half-life — when the suture stops doing its job
  • Complete absorption — when the material physically disappears

The first is what you care about clinically. A suture that is fully absorbed at 90 days but has lost all strength by day 10 is no use for fascia.

Non-absorbable sutures retain strength indefinitely (or near enough). Used where permanent support is needed — mesh fixation, vascular anastomosis, tendon — or where the suture will be removed.


3. Monofilament vs Braided

MonofilamentBraided (multifilament)
StructureSingle strandMultiple filaments twisted or braided
Infection riskLower — no interstices for bacteria to hide inHigher — bacteria can sit between filaments where phagocytes cannot reach
HandlingStiffer, more memory, harder to tieSofter, better handling
Knot securityPoorer — needs more throwsBetter — holds with fewer throws
Tissue dragLow — passes smoothlyHigher — "sawing" effect
Use whereContaminated fields, skin, vascular, fasciaClean fields, ligatures, bowel, where handling matters

The practical consequence: in a contaminated field — perforated bowel, abscess, infected mesh — reach for monofilament. In a clean field where you want a secure knot and good handling, braided is fine.


4. Suture Sizing (USP)

Counterintuitive and worth being certain about:

Larger → smaller:

5 · 4 · 3 · 2 · 1 · 0 · 2-0 · 3-0 · 4-0 · 5-0 · 6-0 · 7-0 · 8-0 · 9-0 · 10-0

More zeros = thinner. So 5-0 is much finer than 2-0, and 1 is thicker than 0.

SizeTypical use
1, 2Abdominal mass closure, tendon, orthopaedic
0, 2-0Fascia, mesh fixation, large vessel ligature, bowel seromuscular
3-0Bowel anastomosis, subcutaneous, skin on trunk, standard ligature
4-0Subcuticular skin, small bowel, face on trunk
5-0, 6-0Vascular anastomosis, facial skin, paediatric
7-0 and finerMicrovascular, ophthalmic

5. The Sutures You Will Actually Use

Absorbable

SutureMaterialStructure50% strength lostFully absorbedTypical use
VicrylPolyglactin 910Braided~2–3 weeks56–70 daysBowel, subcutaneous, ligatures, general workhorse
Vicryl RapidePolyglactin 910 (irradiated)Braided~5 days~42 daysSkin where sutures shouldn't need removal, perineum, paediatric
MonocrylPoliglecaprone 25Monofilament~1 week91–119 daysSubcuticular skin closure
PDS IIPolydioxanoneMonofilament~4 weeks (25% at 6 weeks)183–238 daysAbdominal mass closure, slowly healing tissue
Monoderm / MonosynVariousMonofilament~1–2 weeks~60–90 daysUnit-specific Monocryl equivalents
V-Loc / StratafixBarbed (PDO or polyglactin)Monofilament/braidedVaries by typeVariesLaparoscopic closure — no knot needed

Catgut (plain and chromic) is no longer available in the UK and EU — withdrawn over BSE transmission concerns. It still appears in older textbooks and older consultants' vocabulary. If asked, know it was a natural absorbable material degraded by proteolysis with a marked inflammatory response.

Non-absorbable

SutureMaterialStructureNotes
ProlenePolypropyleneMonofilamentInert, minimal reaction, blue. Vascular anastomosis, mesh fixation. Very slippery — needs extra throws
EthilonNylon (polyamide)MonofilamentSkin closure, drain fixation. Slowly degrades (~15–20% per year)
EthibondPolyesterBraidedStrong, good handling. Cardiac, tendon, some mesh
SilkNatural (silkworm)BraidedExcellent handling, poor long-term strength, marked tissue reaction. Largely superseded but still used for drain fixation and some ligatures
PTFE (Gore-Tex)ePTFEMonofilamentVascular grafts
SteelStainless steelMono or multiSternal closure

6. Needles

More marks are lost on needles than on suture material.

Point type

TypeCross-sectionUse
Conventional cuttingTriangular, cutting edge on the inner (concave) curveSkin. Tends to cut towards the wound edge
Reverse cuttingTriangular, cutting edge on the outer (convex) curveSkin, tough tissue. Cuts away from the wound edge — less likely to cut out. The default for skin
Round-bodied (taper)Round, tapers to a pointBowel, vessels, fat, peritoneum, muscle — separates tissue fibres rather than cutting them
Taper-cutRound body with cutting tipTough fibrous tissue, vascular grafts, calcified vessels
BluntRounded tipFascia, liver, kidney. Reduces needlestick injury — recommended for abdominal mass closure

The one-line version: cutting for skin, round-bodied for everything inside, blunt for fascia and friable solid organs.

Curvature

Circle fractionUse
1/4Ophthalmic, microsurgery
3/8Skin and superficial tissue — the most common
1/2Deep or confined spaces — bowel anastomosis, pelvis
5/8Very deep and confined — urology, laparoscopic suturing
Straight (Keith)Skin, occasionally percutaneous
J-shapedLaparoscopic port site closure

Loop sutures (e.g. 1 PDS loop) have the needle swaged to a doubled strand — used for mass closure so you can anchor without a knot at one end.


7. What to Use Where — Quick Reference

Abdominal wall

LayerDefault
Midline fascia (mass closure)1 PDS loop, continuous, blunt or taper needle. 4:1 suture-to-wound-length ratio. Small bites: 5 mm from edge, 5 mm apart (STITCH trial — halves incisional hernia rate vs large bites)
PeritoneumDo not close separately — no benefit, adds adhesions
Fat / subcutaneousGenerally do not close. If a large dead space, 3-0 Vicryl interrupted
Skin — clean, cosmetic3-0 or 4-0 Monocryl subcuticular continuous
Skin — emergency, contaminated, obeseStaples or 3-0 nylon interrupted. Easier to remove selectively if infected
Skin — childrenAbsorbable (Monocryl or Vicryl Rapide) — avoids a traumatic removal
Laparoscopic port ≥10 mm0 or 2-0 Vicryl to fascia, J-needle or port closure device

Bowel

TaskDefault
Hand-sewn anastomosis3-0 PDS or 3-0 Vicryl, round-bodied, single layer extramucosal continuous or interrupted
Enterotomy closure3-0 PDS or Vicryl, transverse to avoid narrowing
Appendix stumpEndoloop (0 or 2-0 Vicryl), or 2-0 Vicryl purse-string
Duodenal perforationGraham omental patch — 2-0 or 3-0 Vicryl/PDS interrupted, tied over viable omentum
Stoma maturation3-0 Vicryl Rapide or Monocryl, seromuscular to dermis
Mesenteric defect3-0 Vicryl continuous

Hernia

TaskDefault
Open inguinal (Lichtenstein) mesh fixation2-0 Prolene continuous to inguinal ligament, interrupted to conjoint tendon
Open umbilical / small ventral0 or 2-0 Prolene or PDS; mesh if defect >1–2 cm
Laparoscopic meshTacks, glue, or transfascial 0 Prolene sutures
Femoral0 Prolene, or mesh plug

Vascular

TaskDefault
Aorta3-0 or 4-0 Prolene, double-armed
Femoral / iliac5-0 Prolene
Distal / tibial6-0 or 7-0 Prolene
Arteriotomy closure5-0 or 6-0 Prolene, ± patch

Always double-armed, always monofilament, always non-absorbable. Follow the curve of the needle; never force it through arterial wall.

Other

TaskDefault
Gallbladder cystic ductClips (Hem-o-lok or metal). 2-0 Vicryl tie if wide or friable
Drain fixation2-0 silk or nylon
Chest drain1 or 0 silk / nylon
Perineal / anal wounds3-0 Vicryl Rapide
Breast3-0 Vicryl to deep tissue, 4-0 Monocryl subcuticular
Thyroid skin4-0 or 5-0 Monocryl subcuticular, or tissue adhesive

8. Knots and Throws

  • Braided sutures hold with fewer throws — 3 to 4 is usually sufficient.
  • Monofilament is slippery and has memory — 5 to 6 throws minimum, and more for Prolene.
  • Barbed sutures need no knot but must not be back-tracked — cut flush and bury the tail.
  • A surgeon's knot (double throw first) resists slippage while you place the second throw — useful under tension.
  • Square knots, not granny knots. A granny knot slips under load and is a genuine cause of anastomotic leak and haemorrhage.
  • Tie with the tissue, not against it — the knot should sit down without blanching the tissue. Tissue that blanches is tissue that will necrose.

PART TWO — INSTRUMENTS


9. Scalpels

BladeShapeUse
10Curved bellyGeneral skin incision — the standard
11Straight, pointedStab incisions — abscess drainage, arteriotomy, port sites
15Small curvedFine, precise work — skin lesions, paediatric
20–23Large curvedLarge incisions, laparotomy in bigger patients

Always pass a scalpel in a kidney dish or neutral zone, never hand to hand.


10. Forceps (Tissue Grasping)

InstrumentCharacterUse
DeBakeyLongitudinal ridges, atraumaticBowel, vessels — the default for anything you intend to keep
Lane's / Bonney'sToothed, heavyTough tissue — fascia, aponeurosis
AdsonFine, toothed or non-toothedSkin closure, delicate work
GilliesToothed, angledSkin
Dressing (non-toothed)Serrated, flatSwabs, dressings, packing — not bowel

The rule: toothed for skin and fascia, atraumatic (DeBakey) for bowel and vessels. Crushing bowel with toothed forceps is the classic novice error and it shows.


11. Scissors

InstrumentCharacterUse
MayoHeavy, blunt tips, straight or curvedCutting sutures and tough tissue. Straight for suture, curved for tissue
Metzenbaum ("Metz")Fine, long shanks, short bladesDelicate tissue dissection — the workhorse for opening planes
McIndoeFine, curvedPlastic and fine dissection
PottsFine, angled 45°/60°Arteriotomy extension — vascular only
IrisVery fine, sharpFine cutting, skin

Never cut suture with Metzenbaums. Blunting a pair of Metz in front of the scrub nurse is a memorable way to be remembered.


12. Haemostats and Clamps

InstrumentCharacterUse
Mosquito (Halstead)Small, fine, curved or straightSmall vessels, fine dissection
Spencer WellsMedium artery forcepsGeneral haemostasis, the standard clip
Kelly / RobertsLarger, heavierLarger pedicles, deeper tissue
Mixter / Lahey (right-angle)Right-angled tipPassing ties around a pedicle or duct — cystic duct, vessels
DoyenLong, flexible, non-crushingOccluding bowel you intend to keep
Lang Stevenson / PayrCrushingBowel you are resecting
SatinskyCurved, side-biting, vascularPartial occlusion of a great vessel
BulldogSmall spring clampTemporary vascular occlusion
DeBakey / Fogarty vascular clampsAtraumatic jawsArterial control

Non-crushing on the side you're keeping, crushing on the specimen side. Get this the wrong way round and you have devitalised the bowel you are about to anastomose.


13. Grasping Instruments

InstrumentCharacterUse
BabcockBroad, atraumatic, fenestratedBowel, appendix, fallopian tube — grasping without crushing
AllisToothed, interlockingTough tissue, fascia, specimen. Not on bowel you are keeping
DuvalTriangular, broadLung, bowel, gallbladder
LittlewoodToothed, heavyFascia, skin edges
Lane's tissueHeavy, toothedTough structures
KocherHeavy, toothed with transverse ridgesFascia, tough pedicles. Crushing

14. Retractors

Hand-held

InstrumentUse
LangenbeckSmall, L-shaped — superficial retraction, hernia, thyroid
MorrisMedium, right-angled — abdominal wall
DeaverLarge, curved, flat — deep abdominal retraction, liver
KellyLarge right-angled — abdominal wall
CzernyDouble-ended, forked and blade
Malleable copperBendable — shape to what you need, protect viscera

Self-retaining

InstrumentUse
Travers / WestSmall self-retainer — superficial wounds, hernia
Norfolk & NorwichLarger self-retainer
BalfourAbdominal self-retainer with lateral blades and central bladder blade
Bookwalter / Omni-TractTable-mounted ring retractor systems — major open abdominal work
Gelpi / WeitlanerSharp-pronged self-retainers — superficial, orthopaedic, spinal
NathansonLiver retractor — laparoscopic upper GI
Alexis / wound protectorCircumferential wound protection and retraction — reduces SSI

15. Needle Holders

InstrumentUse
Mayo-HegarStandard, heavy — the general workhorse
Crile-WoodFiner jaws, longer — bowel, deeper work
CastroviejoFine, spring-loaded, locking — vascular, microsurgery
GilliesCombined needle holder and scissors — skin closure. Note: no ratchet, so it relies on grip

Hold the needle at two-thirds along from the tip, at right angles to the holder. Load it in the tip of the jaws, not the heel.


16. Laparoscopic Instruments

InstrumentUse
Veress needleClosed entry — insufflation before first port
Hasson portOpen (cut-down) entry — safer, preferred in previous surgery
Optical portVisual entry under direct vision
Johann grasperAtraumatic fenestrated grasper — bowel, gallbladder
Maryland dissectorCurved fine dissector — the workhorse for Calot's triangle
Hook diathermyMonopolar hook — dissection and division
EndoloopPre-tied ligature — appendix stump
Hem-o-lok / clip applierPolymer or metal clips — cystic duct and artery
Fan retractorLiver or bowel retraction
EndobagSpecimen retrieval without port-site contamination
Endo GIA / Endo staplerDivision and anastomosis

Port sizes: 5 mm (most instruments), 10–12 mm (camera on some systems, stapler, clip applier, specimen retrieval). Close fascia on any port ≥10 mm to prevent port-site hernia.


17. Staplers

Types

StaplerFunction
Linear cutter (GIA)Places two double rows of staples and divides between — side-to-side anastomosis, bowel division
Linear non-cutting (TA)Places staple rows without cutting — closing a stump
Circular (EEA / CEEA)End-to-end anastomosis — colorectal, oesophagogastric. Sizes 25–33 mm
Endo GIALaparoscopic linear cutter, articulating
Skin staplerSkin closure

Cartridge colours (Endo GIA / tri-staple — check your system, colours vary by manufacturer)

ColourClosed staple heightTissue
Grey / white~2.0–2.5 mmVascular — mesentery, vessels
Blue~3.5 mmStandard bowel, lung
Gold~3.8 mmIntermediate thickness
Green~4.8 mmThick tissue — stomach, thickened bowel
Black~5.0 mm+Thickest tissue

Get this wrong in either direction and you have a problem: too short a staple on thick tissue tears through and bleeds or leaks; too tall a staple on thin tissue fails to appose and leaks. Feel the tissue, and when in doubt go one size taller.

Always allow the stapler to compress for 15–30 seconds before firing — this allows fluid to displace and improves staple formation.


18. Energy Devices

DeviceMechanismSeals vessels up to
Monopolar diathermyCurrent from active electrode through patient to return plate~1–2 mm
BipolarCurrent passes only between the two limbs of the forceps~2–3 mm
Advanced bipolar (LigaSure)Bipolar with feedback-controlled pressure and energy7 mm
Ultrasonic (Harmonic)Mechanical vibration at ~55 kHz, coagulates by protein denaturation, less thermal spread5 mm
Combination (Thunderbeat)Ultrasonic + advanced bipolar7 mm

Key safety points:

  • Cutting mode — continuous waveform, less coagulation. Coagulation mode — interrupted waveform, more heat.
  • Return plate over well-perfused muscle, away from bony prominences, scars and metal implants. Burns occur from increased current density at a partially detached plate.
  • Cardiac devices: prefer bipolar; if monopolar essential, short bursts, plate sited so current does not cross the device, post-operative check.
  • Ultrasonic blades stay hot for several seconds after activation — a common cause of inadvertent injury.

19. Mesh

TypeMaterialUse
Polypropylene (heavyweight)Permanent syntheticTraditional inguinal repair; stiffer, more contraction
Polypropylene (lightweight / large pore)Permanent syntheticPreferred for inguinal — less chronic pain, better compliance
Composite / barrier-coatedPolypropylene with ePTFE or collagen barrierIntraperitoneal placement (IPOM) — barrier faces bowel to reduce adhesion and fistula
BiologicalAcellular dermal matrix (porcine, bovine, human)Contaminated or infected fields. Expensive; high recurrence rates
Biosynthetic / absorbablePoly-4-hydroxybutyrate, glycolide copolymersContaminated fields; scaffold that is resorbed

Never place bare polypropylene in direct contact with bowel — adhesion, erosion and enterocutaneous fistula are the consequence.


20. Drains

DrainTypeUse
RobinsonClosed, passiveGeneral abdominal
RedivacClosed, active suctionBreast, thyroid, dead-space obliteration
BlakeClosed, fluted, suctionCardiothoracic, abdominal
CorrugatedOpen, passiveAbscess cavities, superficial
Chest drainClosed, underwater sealPneumothorax, haemothorax, empyema
Yeates / sumpOpen or closedHigh-output cavities

Evidence position: routine drainage after most abdominal surgery — including colorectal anastomosis and cholecystectomy — does not reduce complications and is discouraged by ERAS protocols. Drain when there is a specific indication (dead space, pancreatic anastomosis, infected cavity, bile leak concern), not by habit.


PART THREE — WALKING INTO A CASE


21. What to Ask Before You Scrub

If you're returning to operating after time away, these five questions save you every time:

  1. "What's your preference for closure here?" — pre-empts the mid-operation guess.
  2. "Which stapler and cartridge do you use for this?" — colours and preferences vary between units.
  3. "Do you want a drain?" — and if so, which and where.
  4. "Any kit I should know about that's changed?" — energy devices and mesh brands turn over quickly.
  5. "How do you like the patient positioned?" — asked before the patient is asleep, not after.

None of these make you look inexperienced. Asking them makes you look like someone who has been in a lot of theatres and knows preferences differ.


22. Common Trays — What's Usually In Them

General set: scalpel handles, DeBakey and toothed forceps, Mayo and Metzenbaum scissors, Spencer Wells and mosquito clips, needle holders, Langenbeck and Morris retractors, Allis and Babcock, sucker, diathermy.

Laparotomy set: as above plus Deaver and Kelly retractors, Balfour self-retainer, bowel clamps (Doyen, crushing), long instruments, malleable retractors, packs.

Laparoscopic cholecystectomy: Veress or Hasson, 10 mm and 5 mm ports, 30° scope, Maryland dissector, hook diathermy, Johann graspers, clip applier, endobag, irrigation-suction.

Appendicectomy (lap): three ports, graspers, hook, Endoloop or stapler, endobag.

Hernia (open): general set, Langenbeck, self-retainer, mesh, 2-0 Prolene.

Emergency laparotomy: laparotomy set, wound protector, staplers with a range of cartridges, stoma kit, large packs, cell salvage if available.


23. A Note on Returning to Operating

Skills degrade less than confidence does. The things that genuinely fade after a year away are speed, instrument vocabulary, and the automatic knowledge of what comes next — not judgement or anatomy.

Practical things that help:

  • Ask for a supported return — most deaneries have a formal returning-to-practice framework (SuppoRTT in England), with funded refresher time, simulation, and a phased return. Use it; it exists for exactly this.
  • Start with cases you know well. Confidence returns fastest with three straightforward lap choles, not one difficult redo.
  • Say what you're doing out loud while operating for the first few lists. It slows you slightly and organises your thinking considerably.
  • Watch one before doing one for anything you haven't done in over a year. Nobody thinks less of a registrar who says "I'd like to see one first" — and everyone notices the one who doesn't.
  • Check what changed. Guidelines, kit, and unit protocols move in a year. Ask the scrub team what's new — they always know first.

This guide reflects general UK practice as of August 2026. Instrument names, suture preferences, stapler cartridge colours and mesh availability vary between manufacturers and between units — always confirm locally. Educational resource; not a substitute for supervised training or clinical judgement.

Revising for the MRCS?Try the question bank— free questions to start, no card needed.

For educational use only. Always check your local trust protocol and the current guideline position before acting on anything here.